Diagnostic accuracy of dental pulse oximeter with customized sensor holder, thermal test and electric pulp test for the evaluation of pulp vitality: an in vivo study
DOI:
https://doi.org/10.14295/bds.2020.v23i1.1805Abstract
Background: the efficiency of the diagnostic aids plays an important role in the treatment plan. This study aims to assess the diagnostic accuracy of dental pulse oximeter with a customized sensor holder, thermal test and electric pulp tester in assessing the actual pulp status and to evaluate the oxygen saturation level in control healthy teeth, non-vital and teeth with irreversible pulpitis. Material and methods: thirty-seven single canal teeth requiring endodontic therapy were included in the study. The selected teeth were tested with dental pulse oximeter, electric pulp test, cold spray, and heated gutta percha stick. Between each test a time lag of 2 minutes was allowed for the central sensitization to occur. Three blinded operators were involved in the study. The actual status of the pulp was evaluated after the initiation of endodontic treatment. To assess the actual pulp status direct visual examination of access cavity as performed. The data was statistically analysed using (ANOVA) Analysis of Variance and Post-hoc Tukey test. Results: sensitivity of pulse oximeter, heat test, cold and electric pulp test, was 100, 25, 50, and 12, respectively. The specificity of these tests was 100, 72 81, and 77, respectively. The ANOVA showed that there was statistical difference between all the groups (p=0.0005). Post-Hoc Tukey revealed that there was statistical difference among all the groups, nonvital group (p=0.0005), control group (p=0.01) and for irreversible pulpitis (p=0.01). The overall diagnostic accuracy of pulse oximeter was 100% followed by cold test 66%, heat test to be 49% and electric pulp test to be 45%. Conclusion: the custom-made holder used in the present study aided in providing accurate response for pulp vitality testing. In this study the diagnostic accuracy was high with dental pulse oximeter followed by cold, heat and the least was electric pulp tester in different pulpal conditions.
KEYWORDS
Cold test; Heat test; Oxygen saturation; Pulse oximeter; Vitality tests.
Downloads
Published
Issue
Section
License
COPYRIGHT TRANSFER AND RESPONSIBILITY STATEMENT
(PDF)
For all articles published in the BDS journal, copyright is retained by the authors. Articles are licensed under an open-access Creative Commons CC BY 4.0 license, meaning that anyone may download and read the paper for free. In addition, the article may be reused and quoted, provided that the original published version is cited. These conditions allow for maximum use and exposure of the work while ensuring that the authors receive proper credit. All metadata associated with published articles is released under the Creative Commons CC0 Universal Public Domain Dedication.
Before the submission, authors must obtain permission to reproduce any published material (figures, schemes, tables, or any extract of a text) that does not fall into the public domain or for which they do not hold the copyright. Permission should be requested by the authors from the copyright holder (usually the Publisher, please refer to the imprint of the individual publications to identify the copyright holder).
The authors hereby attest that the study is original and does not present manipulated data, fraud, or plagiarism. All names listed made a significant scientific contribution to the study, are aware of the presented data, and agree with the final version of the manuscript. They assume complete responsibility for the ethical aspects of the study.
This text must be printed and signed by all authors. The scanned version should be submitted as supplemental file during the submission process.