Effect of relining and microwave disinfection on the dimensional stability of denture bases

Autores

  • Paula Carolina Komori de Carvalho Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Faculdade de Odontologia, Departamento de Materiais Odontológicos e Prótese. São José dos Campos, SP, Brazil. https://orcid.org/0000-0002-9411-5719
  • Fernanda Calvo Costa ICT/UNESP - São José dos Campos https://orcid.org/0009-0006-8276-9148
  • Natassia Bricks Bourg Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Faculdade de Odontologia. São José dos Campos, SP, Brazil. https://orcid.org/0009-0003-8084-8318
  • Alexandre Luiz Souto Borges Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Faculdade de Odontologia, Departamento de Materiais Odontológicos e Prótese. São José dos Campos, SP, Brazil. https://orcid.org/0000-0002-5707-7565
  • Tarcisio José de Arruda Paes Junior Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Faculdade de Odontologia, Departamento de Materiais Odontológicos e Prótese. São José dos Campos, SP, Brazil. https://orcid.org/0000-0001-8446-0474

DOI:

https://doi.org/10.4322/bds.2026.e4763

Resumo

Objective: To evaluate the effect of microwave disinfection on dimensional stability of acrylic resin denture base and relined. Material and Methods: 24 maxillary complete dentures were assigned to 2 groups; GA - acrylic base (Power microwave, Vipi-Wave) and GR - relined (New Truliner). For all prosthesis the thickness of the base, reliner and tooth position were completely standardized. The intact and relined denture bases were divided into 3 groups and evaluated after: polymerization (C - control group); microwave disinfection (D); microwave disinfection + water storage for 14 days (D14). Microwave disinfection was performed for 3 min at 650W. The alteration of tooth position of each group was measured comparing the images imported to Image Tool software. The linear distance between different points marked on each side of the arch (canine, molar and incisor) made before polymerization served as baseline and after. Differences between the baseline and those subsequently were used to calculate the percent of dimensional changes. Results: The relined dentures without disinfection (GR-C) showed an average increase in tooth position distances of approximately 10.4% (± 5.2%), indicating dimensional expansion. Immediate microwave disinfection caused a significant decrease in distances in both acrylic base (GA-D: ~8.9% reduction ± 3.7%) and relined groups (GR-D: ~6.6% reduction ± 3.5%), reflecting material contraction. After disinfection plus 14 days water storage (D14), dimensional changes were minimal, close to control values (GA-D14: ~1.7% decrease ± 2.1%; GR-D14: ~0.9% decrease ± 1.7%). Conclusion: The microwave disinfection influenced tooth position regardless of relining.

KEYWORDS

Acrylic resin; Complete denture; Dental prosthesis; Disinfection; Microwave.

Downloads

Não há dados estatísticos.

Publicado

2025-12-19

Como Citar

1.
Carvalho PCK de, Calvo Costa F, Bourg NB, Borges ALS, Paes Junior TJ de A. Effect of relining and microwave disinfection on the dimensional stability of denture bases. BDS [Internet]. 19º de dezembro de 2025 [citado 20º de dezembro de 2025];29(1):e4763. Disponível em: https://ojs.ict.unesp.br/index.php/cob/article/view/4763