Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth
DOI:
https://doi.org/10.14295/bds.2014.v17i3.993Resumo
Objective: This clinical study evaluated the success of two different splint materials bonded on periodontally treated mobile teeth.
Methods: A total of 14 patients were included in the study. Patients were randomly assigned to the groups to receive either with or wire composite splint (WCS) or fiber-reinforced composite splint (FCS). Clinical periodontal parameters were performed and periotest values were recorded at baseline, and after 6 and 12 months. Patients were asked to complete a self-administered questionnaire after the splinting procedures. Failure types for the splints were categorized.
Results: Baseline PI values showed significant decrease at 6 month follow up in the WCS (p=0.0019) and FCS (p<0.0001) groups and remained stable after 12 months (WCS; p=0.36, FCS; p=0.63). During the course of the study, PD and RD values exhibited no change between and within groups. Clinical parameters including PD, RD, PI and BOP were stable at 6 and 12 months follow-up period. In 6 patients (4 FCS, 2 WCS), reparable failures occurred during the observation period. In four patients (3 FCS, 1 WCS) splints failed completely and were removed. The periotest values of the failing teeth ranged between 47.3 and 50. In 3 patients in the WCS and 1 patient in the FCS group, periotest values were ? 40 but no splint failures were observed.
Conclusion: FCS tends to show increased mechanical limitations compared to WCS. Teeth with periotest values above 40 may be more prone to splint failures independent of the splint material.
Downloads
Downloads
Arquivos adicionais
Publicado
Como Citar
Edição
Seção
Licença
TRANSFERÊNCIA DE DIREITOS AUTORAIS E DECLARAÇÃO DE RESPONSABILIDADE
Toda a propriedade de direitos autorais do artigo "____________________________________________________________________" é transferido do autor(es) para a CIÊNCIA ODONTOLÓGICA BRASILEIRA, no caso do trabalho ser publicado. O artigo não foi publicado em outro lugar e não foi submetido simultaneamente para publicação em outra revista.
Vimos por meio deste, atestar que trabalho é original e não apresenta dados manipulados, fraude ou plágio. Fizemos contribuição científica significativa para o estudo e estamos cientes dos dados apresentados e de acordo com a versão final do artigo. Assumimos total responsabilidade pelos aspectos éticos do estudo.
Este texto deve ser impresso e assinado por todos os autores. A versão digitalizada deverá ser apresentada como arquivo suplementar durante o processo de submissão.