The influence of disinfection on dimensional stability of temporary crowns

Autores

  • Paula Carolina Komori de Carvalho São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil. http://orcid.org/0000-0002-9411-5719
  • Sâmia Carolina Mota Sacourague São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.
  • Lais Medeiros Ribeiro de Almeida São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.
  • Estevão Tomomitsu Kimpara São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.
  • Tarcisio José de Arruda Paes-Junior São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.

DOI:

https://doi.org/10.14295/bds.2018.v21i3.1573

Resumo

Objective: Evaluate the influence of different disinfection methods on the dimensional stability of temporary acrylic resin crowns. Material and Methods: A metallic die with two different marks at the margin was used to prepare the specimens with two different resins (bis-acrylic resin-Structur, acrylic resin-Dencrilay). They were divided into eight groups (n=8), determined according to the disinfection methods (microwave, acetic acid, 1% hypochlorite) and control. The marginal adaptation was recorded using an optical microscope (50X) comparing two different marks on the margin of the crowns with 2 points along the entire circumferential margin before and after disinfection methods. Results: Results were compared statistically by ANOVA and Tukey's test (p?0.05). The two-way ANOVA showed statistical difference between types of materials. No significant differences were found between disinfection methods and interaction of factors. Conclusion: All procedures affected the marginal adaptation however temporary crowns made by bis-acrylic resin demonstrate higher dimensional stability.

Keywords

Dimensional stability; Disinfection; Temporary crowns.

Downloads

Não há dados estatísticos.

Biografia do Autor

Paula Carolina Komori de Carvalho, São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.

Department of Dental Materials and Prosthodontics

Estevão Tomomitsu Kimpara, São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.

Department of Dental Materials and Prosthodontics

Tarcisio José de Arruda Paes-Junior, São Paulo State University (Unesp) – Institute of Science and Technology – São José dos Campos – Department of Dental Materials and Prosthodontics – SP – Brazil.

Department of Dental Materials and Prosthodontics

Downloads

Publicado

2018-08-01

Como Citar

1.
de Carvalho PCK, Sacourague SCM, de Almeida LMR, Kimpara ET, Paes-Junior TJ de A. The influence of disinfection on dimensional stability of temporary crowns. BDS [Internet]. 1º de agosto de 2018 [citado 18º de setembro de 2025];21(3):302-6. Disponível em: https://ojs.ict.unesp.br/index.php/cob/article/view/1573

Edição

Seção

Artigos de Pesquisa Clínica ou Laboratorial

Artigos mais lidos pelo mesmo(s) autor(es)

1 2 > >>