Evaluation of light transmission and uniformity of hardening of resin cements as a function of simulated indirect restoration thickness

Authors

  • Luana dos Santos Souza Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Departamento de Odontologia Restauradora. São José dos Campos, SP, Brazil. https://orcid.org/0000-0003-3173-8422
  • Sandy Vitória dos Santos Osório Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Departamento de Odontologia Restauradora. São José dos Campos, SP, Brazil. https://orcid.org/0009-0006-6292-2045
  • Maria Fernanda Monnerat Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Departamento de Odontologia Restauradora. São José dos Campos, SP, Brazil. https://orcid.org/0000-0001-5979-8975
  • Taciana Marco Ferraz Caneppele Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Departamento de Odontologia Restauradora. São José dos Campos, SP, Brazil. https://orcid.org/0000-0003-0521-7922
  • Eduardo Bresciani Universidade Estadual Paulista, Instituto de Ciência e Tecnologia, Departamento de Odontologia Restauradora. São José dos Campos, SP, Brazil. https://orcid.org/0000-0001-9299-8792

DOI:

https://doi.org/10.4322/bds.2025.e4815

Abstract

Objective: This study evaluated how the thickness of a simulated indirect restoration influences the light transmission of curing units and the uniformity of dual-cure resin cement polymerization using two light sources. (VALO – ULTRADENT and RADII-CAL – SDI). Material and Methods: Sixty A2-shade resin composite discs (GrandioSo, VOCO GmbH), 12 mm in diameter, were fabricated and divided into three experimental groups by thickness: 1.5 mm, 2.5 mm, and 3.5 mm (n = 10 per group). For irradiance transmission, light passage through each disc was measured using a radiometer (ECEL RD-7). The same discs were used in an indirect restoration simulation (SRI), employing a 3D-printed mold with 0.3 mm lateral barriers to ensure uniform cement thickness. Dual-cure resin cement (Bifix QM Universal, VOCO GmbH) was applied, and light-curing was performed for 60 seconds with each light source. After 24 hours, Knoop microhardness was assessed in three regions of the cement: central, intermediate, and peripheral region. Light transmission was analyzed by two-way ANOVA, while cement microhardness was assessed by three-way ANOVA, followed by Tukey’s post-hoc test (α=0.05). Results: Light transmission was undetectable through 3.5 mm specimens, indicating increased attenuation with thickness. VALO showed higher irradiance (67.6 ± 9.69 mW/cm2) than RADII-CAL (57.3 ± 13.82 mW/cm2). Cement microhardness decreased as restoration thickness increased, with the highest value at 1.5 mm using VALO (75.4 ± 8.43). Thickness also influenced hardening uniformity, with the highest regional value observed in the center of 1.5 mm specimens (81.5 ± 6.49). Conclusion: We can conclude that thickness directly influences the hardening of dual-cure resin cement, as it is affected by the light attenuation occurring through the indirect restorative material.

KEYWORDS

Cementation; Dental materials; Polymerization; Prosthodontics; Resin cements.

Downloads

Download data is not yet available.

Downloads

Published

2025-11-04

How to Cite

1.
Souza L dos S, Osório SV dos S, Monnerat MF, Caneppele TMF, Bresciani E. Evaluation of light transmission and uniformity of hardening of resin cements as a function of simulated indirect restoration thickness. BDS [Internet]. 2025 Nov. 4 [cited 2025 Nov. 5];28(3):e4815. Available from: https://ojs.ict.unesp.br/index.php/cob/article/view/4815

Issue

Section

Clinical or Laboratorial Research

Plaudit

Most read articles by the same author(s)

1 2 3 > >>